Error Code E CO
Communication error between main MICOM and display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check loose connections at display PCB connectors and hinge wiring connections.
- 2
Reconnect any loose connectors.
- 3
Measure voltage at CON101 18th Pin ~ 16th Pin. Should be 12V. If not 12V: check hinge connection (loose) or replace Main PCB.
- 4
Measure voltage at CON101 10th Pin ~ 16th Pin. Should be 5V. If not 5V: check hinge connection or replace Main PCB.
- 5
Measure voltage at CON101 14th Pin ~ 16th Pin. Should be not 0 or 5V. If 0 or 5V: replace Display PCB.
- 6
Measure voltage at CON101 12th Pin ~ 16th Pin. Should be not 0 or 5V. If 0 or 5V: replace Main PCB.
- 7
Measure voltage at CON5 4th Pin ~ 3rd Pin. Should be not 0 or 5V. If 0 or 5V: replace Display PCB.
- 8
Measure voltage at CON5 5th Pin ~ 3rd Pin. Should be not 0 or 5V. If 0 or 5V: replace Main PCB.
- 9
If all pass: explain to customer.
Other Error Codes for LRFXC2606S
Defect of freezer defrosting sensor
Defect of humidity sensor
Defect of freezer cubed ice maker sensor
Defect of ice maker kit
Defect of freezer cubed ice maker kit
Defect of Cubed Mini ice maker sensor
Defect of ice-room sensor or ice maker sensor
Defect of room temperature sensor